Essential Services — Fire & Smoke Control

Service, maintenance and certification of essential fire and smoke-control systems, including fire/smoke dampers, smoke exhaust, stairwell pressurisation and zone pressurisation.

Fire services

Essential Services — Fire & Smoke Control

Service, maintenance and certification of essential fire and smoke-control systems, including fire/smoke dampers, smoke exhaust, stairwell pressurisation and zone pressurisation.

Technician testing a mechanical fire and smoke damper actuator

Fire & smoke dampers

Work on the mechanical dampers that form part of a building's fire and smoke-control arrangements.

Technician inspecting commercial smoke-exhaust fan equipment

Smoke exhaust

Mechanical smoke-exhaust equipment and its operation within the installed system.

Technician testing airflow in a stairwell pressurisation system

Stairwell pressurisation

Mechanical plant and equipment serving stairwell pressurisation systems.

Technician carrying out functional testing on smoke-control equipment

Related testing

Inspection and testing of the relevant mechanical equipment to the agreed requirements.

Essential services

Maintenance, testing and certification.

From baseline data and damper inspections to system validation and annual certification, our team supports the fire and smoke-control systems in your building.

  • FPA-accredited technicians
  • Integration of fire and smoke control
  • Fire damper inspection and certification
  • Fire damper repairs and installation
  • Essential services validation testing
  • AS1668 / BCA & NCC / Ordinance 70
  • AS1851 maintenance
  • AFSS testing and certification
  • Repairs to essential services
  • Passive fire and smoke systems
  • Fire-isolated exit testing
  • Matrix / cause-and-effect testing
  • Baseline data development

How the systems work together

Smoke out.
Escape routes protected.

A coordinated response from fans, dampers and controls helps extract smoke and protect the route out of a building.

Mechanical smoke controlIllustrative building section
Illustrative three-storey building cutaway: a dedicated ground-level fan supplies the enclosed stairwell on the left; a separate roof-mounted air-handling unit supplies office ducts; the middle fire-floor supply damper is closed and its smoke-exhaust damper is open to the red riser and rooftop exhaust fan.Unaffected floorFire floor / smoke extractionUnaffected floor

Select a number to explore the equipment.

Outside air / supply & pressurisationSmoke extraction

Illustrative system response. Actual operation, controls and testing depend on the building’s installed design and baseline data.

01

Identify and record

Essential services assets are QR coded and logged in our service software.

02

Schedule AS1851 maintenance

The software assigns the relevant AS1851 maintenance checks and schedules our FPA-accredited technicians.

03

Test and retain evidence

Maintenance, matrix / cause-and-effect testing and system performance validation are recorded, with data retained for auditing.

04

Annual certification

The maintenance and test data, together with validation against the relevant standard, are used to endorse the Annual Fire Safety Statement.

Technician inspecting mechanical fire and smoke-control equipment

In your building

Mechanical expertise for fire and smoke systems.

Mechanical fire and smoke-control equipment has a specific role within a building's wider fire-safety arrangements. Understanding the as-installed systems and the required maintenance and testing scope is the starting point. At Noppen, fully qualified FPA-accredited technicians help building owners and facilities teams coordinate the work and its responsibilities.

Testing and records

Understand the system, the test and the next responsibility.

Mechanical fire and smoke-control equipment works within a wider fire-safety arrangement. A useful service description explains which assets are being examined, what a test can establish and how defects or incomplete tests are reported to the building team.

01

Identify the mechanical measures in scope

Fire and smoke dampers, smoke exhaust equipment and stairwell pressurisation have different functions and test needs. A building may contain several of these measures, but an inspection of one does not cover all the others. The starting point is the building’s baseline data, Fire Safety Schedule, as-built drawings and service reports.

The agreed scope should identify the asset, the required access and the reporting responsibility. Work will require coordination with fire-system contractors, building management and a fire engineer where needed.

02

What a damper record can contain

A damper check sheet in the Noppen records identifies each damper and its location, then records whether the blades can close and latch, whether the fusible link and assembly are clear of obstruction, and whether the mounting and surrounding structure appear sound. It records a result and comments for follow-up. This is a useful model of the detail a facilities team needs to locate and prioritise a defect.

An inspection may find an accessible, functioning damper or may reveal a blocked component, damaged fixing or another condition that requires rectification. The report should say what was tested, what was not accessible and what action is recommended. Repair, retest and any formal sign-off are separate steps, subject to the agreed scope and the people authorised to perform them.

03

Why stair pressurisation needs coordinated testing

Stairwell pressurisation involves more than checking that a fan starts. The process records door force, restoration time, airflow at doors and pressure differentials between floors or zones, together with the way adjacent spaces and fire-system responses affect the test. The relevant test method must be confirmed for each stairwell in every building.

Reliable testing also depends on access to the necessary doors and floors, the ability to operate associated systems, and the people needed to observe the results. Where retail areas, car parks and residential levels share a complex, a test can be delayed or left incomplete by access restrictions or another system fault. That limitation should be visible in the report rather than presented as a completed pass.

04

Treat smoke exhaust as a defined system

Mechanical smoke exhaust may involve fans, dampers, controls and interfaces with dedicated fire-safety equipment. The installed design determines which parts of that chain need to respond and what the mechanical contractor is responsible for checking. A BMS display may make status or faults visible where an interface exists, but that display does not replace the dedicated controls or required functional testing.

Before a test or repair is scoped, the team needs the asset schedule, available cause-and-effect information and confirmation of who can operate or isolate each system. The exact deliverables and responsibilities belong in a site-specific proposal.

05

Record defects, limits and retests

A useful handover separates a completed test from an observed defect and from a recommendation for others. A 2019 report recorded a substantial reduction in airflows and door forces after work, while also listing remaining airflow and noise matters. A later 2021 report described tests that could not be completed because of access and system problems. Both records matter when telling the project story accurately.

The client needs to know the measure, its location, the issues, the test condition, any limitation, the proposed next step and whether another party must approve a solution. A subsequent visit or repair should have its own record. Historic improvement is evidence of a completed stage of work, not proof that a building will remain free of defects indefinitely.

Planning the work

Questions worth answering early.

A workable test plan needs the building records, the right people on site and agreement about how incomplete tests or defects will be reported.

01

Which records should be available before the visit?

Besides the building owner’s details, provide the Fire Safety Schedule (FSS), any performance solution, any relevant drawings, asset locations and recent test or defect reports. The team can then identify which mechanical measures are being requested and what information is missing.

02

Who needs to attend or provide access?

Confirm who can release doors, provide access to plant and operate associated fire systems. Depending on the test, building management, a fire-system contractor or a fire engineer may also need to be involved.

03

How will limits and follow-up be handled?

Agree what the report will identify if a measure cannot be accessed or a test cannot be completed, who receives the findings and how rectification or retesting would be authorised. Certification responsibilities need explicit confirmation.

Work with Noppen

Discuss your fire requirements.

Tell us about your site, installed systems and priorities. We will discuss the required scope and the right next step.